ASTM C114 PDF

C – 00 Standard Test Methods for Chemical Analysis of Hydraulic Cement, chemical analysis, compositional analysis, hydraulic cements. ASTM Standards: 2. C 25 Test Methods for Chemical Analysis of Limestone,. Quicklime, and Hydrated Lime. D Specification for Reagent Water. ASTM C accreditation for cement analysis . are within the prescribed limits for iron, so acceptable (according to ASTM-C requirement).

Author: Zumuro Yoramar
Country: Qatar
Language: English (Spanish)
Genre: Technology
Published (Last): 22 December 2012
Pages: 467
PDF File Size: 10.28 Mb
ePub File Size: 2.71 Mb
ISBN: 218-8-52438-171-6
Downloads: 95412
Price: Free* [*Free Regsitration Required]
Uploader: Muramar

Specific chemical test methods are provided for ease aetm reference for those desiring to use them. The final results, when corrected for blank values, should, in either case, be so designated.

ASTM C114 – 15 – Chemical Analysis of Hydraulic Cement

Current edition approved April 15, Prepare three standards, each in duplicate: C Interelement corrections may be used for any oxide standardization provided improved accuracy can be demonstrated when the correction is applied to all seven CRM cements.

A cement shall not be rejected for failure to conform to chemical requirements unless all determinations of constituents involved and all necessary separations prior to the determination of any one constituent are made entirely by these methods. These reagents shall include purity agents, water, repackaged reagents, concentrated acids and ammonium hydroxide, nonstandardized solutions, and indicator solutions.

Historical Version s – view previous versions of standard. Duplicate samples shall be tested on different days. The reference test methods are long accepted classical chemical test methods which provide a reasonably well-integrated basic scheme of analysis for hydraulic cements. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

Active view current version of standard Translated Standard: It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. These test methods cover the chemical analyses of hydraulic cements. Reporting of analyses shall be of the following order: No other units of measurement are included in this standard. Standard A by the mass fraction of Standard A in each of the other standards that is, 0.

  CONCEPTOS FUNDAMENTALES EN LA HISTORIA DEL ARTE WOLFFLIN PDF

A reference test method may be used in preference to an alternative test method when so desired. Recommended Order for Reporting Analyses. No certificate value given. Link to Active This link will always route to the current Active version of the standard.

The alternative test methods generally provide individual determination of specific analytes and may be used alone or as alternates and determinations within the basic scheme at the option of the analyst and as indicated in the individual method. Historical Version s – view previous versions of standard Translated Version s: The alternative test methods generally provide individual determination of specific components and may be used alone or as alternates and determinations within the basic scheme at the option of the analyst and as indicated in the individual method.

Material CRM must be used in the qualification of test methods and analysts. When two or three results do agree within the permissible variation, their average shall be accepted as the correct value.

Specific chemical test methods are provided for ease of reference for those desiring to use them. Qualification for Different Analyses.

Reference test methods and procedures include determination of insoluble residue, silicon dioxide, ammonium hydroxide group, ferric oxide, phosphorus pentoxide, titanium dioxide, zinc oxide, aluminum oxide, calcium oxide, magnesium oxide, sulfur, loss on ignition, sodium and potassium oxides, manganic oxide, chloride, chloroform-soluble organic substances.

Link to Active This link will always route to the current Active version of the standard.

It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Performance Requirements for Rapid Test Methods. If, however, a blank determination is desired for an alternative test method, one may be used and it need not have been obtained ast, with the analysis.

  CHOCIM 1621 PDF

ASTM C – 09 Standard Test Methods for Chemical Analysis of Hydraulic Cement

The reference cement is acceptable if its assigned value agrees with the average referee value within the limits given in column 3 of Table 1. Test results from alternative test methods may be used as a basis for acceptance or rejection when it is clear that a cement does or does not meet the specification requirement. Any test methods of demonstrated acceptable precision and bias may be used for analysis of hydraulic cements, including analyses for referee and certification purposes, as explained in Section 3.

CO2 from the certificate value by the mass fraction of Certified CaCO3 added to that standard percentage added divided by ; multiply the value determined for. A reference test method must be used where an alternative test method is not provided. Active view current version of standard. When an average of either two or three results can be calculated, the calculation shall be based on the three results.

Originally approved in If the two results do not agree within the permissible variation given in Table 1, the determination shall be asttm until two or three results agree within the permissible variation.

Any test methods of demonstrated acceptable precision and bias may be used for analysis of hydraulic cements, including analyses for referee and certification purposes, as explained in Section 3.

Description of Referee Analyses. Referenced Documents purchase separately The documents listed below are referenced within the subject standard but are not provided as part of the standard. It is used for detection and compensation of systematic bias.