BAHRA CABLES CATALOGUE PDF

Bahra Cables Company was established in to serve Saudi & GCC Markets. . This Catalogue is intended for Medium Voltage Power Cables, Aluminum. MEDIUM VOLTAGE POWER CABLES CONTENTS GENERAL 1 INTRODUCTION TECHNICAL 4 INFORMATION Single Core XLPE Insulated. TECHNICAL INFORMATION COPPER CONDUCTOR | STEEL TAPE ARMOURED | /15 ()kV Size mm2 25 35 50 70 95

Author: Kajibar Sakasa
Country: Ethiopia
Language: English (Spanish)
Genre: Business
Published (Last): 2 August 2006
Pages: 95
PDF File Size: 20.94 Mb
ePub File Size: 18.55 Mb
ISBN: 161-2-37835-246-8
Downloads: 56631
Price: Free* [*Free Regsitration Required]
Uploader: Niramar

A non-hygroscopic polypropylene filler is applied between laid up cores to providea circular shape to the cable. The basis of the standard conditions is the climate conditions of the Kingdom of Saudi Arabia, which are: Voltage between phases conductors 2. Bahra Cables Factory occupies over ,square meters of prime manufacturing space together with associated design offices, laboratoriesand storage area.

View in Fullscreen Report. If the water came inside the cables to insulation, for cables suitable for wet location, practically dry the defected portion before repair. A recommended minimum bending radius is included in Table 2; the cable jacket may be damaged if the cable is bended in diameters less than these values.

Bahra Cables Medium Voltage Catalogue

When the end caps have been removed babra ends of the cable should not be exposed to any kind of moisture. To calculate voltage acbles as the following: Bahra Cables Company is committed to the production of the best product quality and service,utilizing cutting edge European Technology in its manufacturing.

When the screening bonded to earth it will also carry out theshort circuit fault current. For cables specified in this standard, a longer period, not exceeding 8 h on any occasion, can be tolerated.

Phase to earth voltage Uo: Read the Cablew Version. The standard sheath color is Black or Red which has a suitable UV proved additive is added to ensure resistance to sunlight.

  LOCUTIONARY ILLOCUTIONARY AND PERLOCUTIONARY ACTS PDF

Flat Touching A Formation Approx. Manufacturing malfunction, which Bahra Cables Company guarantees its product againstany defect or wrong workmanship, meanwhile in case of damage due to this reason, the actionwill be taken as per the submitted warranty letter, and the company will apply the requiredcorrective and preventive actions.

To facilitate the selection of the cable, systems are divided into three categories as follows. The Armouring type couldbe: A Flat Formation Approx.

Csbles excludes transient voltage variations, due, for example, to lightning impulses, fault conditions and rapid connection of loads. Voltage Drop per phase Minimum Bending radius mm The above values are based on the following conditions: System Short Circuit required.

This way, full traceability will be guaranteed from production start to end, by being able to follow up the machines involved and the material used. This layer, which has a very smooth surface, is a transition form the insulatingmaterial where the electric field exists to a conductive metallic screen, where the electricfield is zero, so it will reduce the stress enhancement at the insulation layer.

The shape codes are rmc, round compacted stranded 2. It specializes in Manufacturing and Distributing Electric Cables.

From start up with wire drawing lines to extrusion lines, to assembly machines up to the laboratories and the final test fields, all technical equipment is provided with the highest European standards of electronic control equipment and measuring devices which insures that the requirements of different quality standards are met. No breakdown catlogue occur.

Such protrusions into the insulation or into the semi-conducting layer increase the localized stress that may exceed the long-term breakdown strength of the insulation, so the semi-conductive layer is acting as a stress control layer. The organization has a lean vertical management structure which is designed to integrate witha highly developed IT-based structure.

This layer acts to smooth out any irregularities and thus reduces the probability of protrusions into the insulating layer. Voltage between phase and earth VC: By keeping such standard of installation and operation, Low Voltage cables can survive in service for a time of 25 years or more without failure.

  AUF DER VOGELWIESE NOTEN PDF

Short circuit for 1 secondData about short circuit are tabulated in construction tables Medium Voltage updated LowRes.

Fire or excessive temperature at the cables location. Please contact the Technology Department for any query. Our state of art testing equipments and the strict quality procedures ensure the product quality and integrity so we can guarantee that our cables are defect free and suitable for the intended application through the cable service lifetime.

A 2- Laid in free air both end bonded 0. Lifting cable drums using crane. The protective cable end cap should not beremoved from the ends of the cable until immediately prior to termination or jointing, especiallyfor cables that do not have extruded bedding.

Bahra Cables Medium Voltage Catalogue Pages 1 – 50 – Text Version | FlipHTML5

Such tape s will bind the cores together and prevent them from opening nahra as a separator between different polymers used in a cable and works as a heatbarrier between the cores and the extruded bedding. It is based inBahra industrial city catalogje 25km from Jeddah. The volume resistivity of thisexternal layer is limited to meter-ohms.

A A 2- Laid in free air both end bonded Trefoil Formation Approx. The total available stock yard for drum storage is more than 80,sqm.

Cables are often supplied in heavy cable reels and handling these reels can constitutea safety hazard. The PVC or PE jacketing material is very stable against most of bhara Chemical traces could be existing at the soil, these material with Black colour Master batch up to 2.